Check Valves
Smolensky Check Valves
The smolensky check valves is the lift check valves added by pass. It can make a function of harmless check valves, dashpot check valves.
- Water Hammer!-The Enemy of Flow Pipeline
The water hammer occurs by sudden flow stopping caused by pump-off or pressure wave caused from the pipes bending.
- Smolensky check valves----No Impact , No Dining.
This commodity is the superb check valves designed to prevent the water impact with the operation of buffer hill&spring inside, thereby the water
hammer&breakage of the pipes can be protected.
When the pump starts, the pressure of the fluid pushes disc(2)then the fluid flows to chamber (c) through the chamber (A)
&(B). When the pump stops, momentarily the pressure in the pipeline falls down then the short stagnation of the flow occurs and the reverse
flow follows soonest. But at the same time by the action of spring(1)&buffer hill (4)disc(2) adheres to body seat(3)therefore any reverse
flow&water hammer can be prevented.
- No water hammer
- No trouble by the simple structure
- Easy repair
- When the repair or replacement of the pipe is done, the water in the body champer is drained by the attached by-pass valves.
- No impact &noise
- Scrupulous &safe check
- No leakage
- Available for the vertical and horizontal piping connection
- Body and other part materials can be selected by customers' requests & sites' conditions
| No |
Name of Part |
Material |
| 1 |
Body |
Cast Iron |
| 2 |
Disc Holder |
Cast Iron |
| 3 |
Buffer |
Cast Iron |
| 4 |
Upper Guide |
Ductile Iron |
| 5 |
Seat Ring |
Bronze |
| 6 |
Disc Washer |
Steel Plate |
| 7 |
Spring |
SS304 |
| 8 |
Soft Seat |
NBR |
| 9 |
Hinge Stem |
SS400 |
| 10 |
Bypass |
Brass |
| 11 |
Bypass |
Brass |
| 12 |
Handle |
Ductile Iron |
Technical Data
| Applicable Fluid |
Water, Oil |
| Applicable Inlet Pressure |
Max,10kgf/ c㎡ |
| Applicable Temperature |
Max.
82℃(Special
Order :Max 120℃) |
| Min, Pressure Different across the Disc |
0.05-----0.1kgf/c㎡ |
| Leakage Allowance |
0 |
| End Connection |
Flanged |
| Hydrostatic Test |
15kgf/c㎡------3min |
|