HOME | SITE DIRECTORY | SHOWROOM | CONTACT
 

Check Valves


Wafer Check Valves Technical Data and Installation

MODEL:WAFER CHECK VALVES(CW1000.CW2000.CW3000,CW4000)

Wafer check valves is a general purpose and one way flow valves. Due to lighter in weight and short dimension, wafer check valves is very easy to be installed between flanges. Inner parts assembled by two semicircle springs and plates, which pinned to the body. Normally closed by spring action and open by fluid pressure. Because the spring cycle reaction is very quick, it could protect the pipe from wafer hammer.

Precautions in piping

  • Lay pipes so that the cast direction of wafer check valves body corresponds with the flow direction.

  • It can be installed in vertical piping. In horizontal piping, set the rib wafer check valves vertically.

  • Use an extension tube between wafer check valves and butterfly valves, never connect the wafer check valves to the valves directly.

  • Avoid entering the end of a tube or gasket within the operating of a radius of the wafer check valves discs.

  • Never mount a reducer just in front of or behind the wafer check valves

  • When installing a wafer check valves near an elbow, leave a space as large as possible between them.

  • When installing a wafer check valves at a pump outlet, leave a space at lease 6 times of valves diameter and be sure that the plate is evenly stressed by fluid.

NO Name Of Part
1 Body
2 Disc
3 Stem
4 Seat
5 Pin Retainer
6 Pin Stabilizer
7 Spring
8 Name Plate
9 Spring Bearings
10 Plate Bearing
11 Body Bearing

Normal Dia 50(2")------700(28") 50(2")------450(18") mm (inch)
Nom.Pressure 1 1.6 Mpa
Test Press Shell 1.5 2.4
Seal 1.1 1.76
Working Tem (癈) -15-----------------+150
Suitable Medium Fresh water, Sewage, Sea water, Air, Steam, Food, Medicine, Oils, Acids, etc.

 

 